TITLE 35: ENVIRONMENTAL PROTECTION
SUBTITLE B: AIR POLLUTION CHAPTER I: POLLUTION CONTROL BOARD SUBCHAPTER c: EMISSION STANDARDS AND LIMITATIONS FOR STATIONARY SOURCES
PART 217
NITROGEN OXIDES EMISSIONS
SECTION 217.184 EMISSIONS LIMITATIONS
Section 217.184 Emissions Limitations
Except as provided for under Section 217.152, on or after
January 1, 2015, no person shall cause or allow emissions of NOx into
the atmosphere from any process heater to exceed the following limitations. Until
July 1, 2025, compliance must be demonstrated with the applicable emissions
limitation on an ozone season and annual basis. On and after July 1, 2025,
compliance must be demonstrated with the applicable emissions limitation on a
30-day rolling average basis.
|
Fuel
|
Emission
Unit Type and Rated Heat Input Capacity (mmBtu/hr)
|
NOx Emissions Limitation (lb/mmBtu) or
Requirement
Before July 1, 2025
|
|
Natural Gas or Other Gaseous Fuels
|
Process heater greater than 100
|
0.08
|
|
|
Process heater less than or
equal to 100
|
Combustion tuning
|
|
Residual
Fuel Oil
|
Process heater greater than
100, natural draft
|
0.10
|
|
|
Process heater greater than
100, mechanical draft
|
0.15
|
|
|
Process heater less than or
equal to 100
|
Combustion tuning
|
|
Other
Liquid Fuels
|
Process heater greater than
100, natural draft
|
0.05
|
|
|
Process heater greater than
100, mechanical draft
|
0.08
|
|
|
Process heater less than or
equal to 100
|
Combustion tuning
|
|
Fuel
|
Emission
Unit Type and Rated Heat Input Capacity (mmBtu/hr)
|
NOx Emissions Limitation (lb/mmBtu) or
Requirement
On and after July 1, 2025
|
|
Natural Gas or Other Gaseous
Fuels
|
Process heater greater than 50
|
0.08
|
|
|
Process heater less than or
equal to 50
|
Combustion tuning
|
|
Residual Fuel
Oil
|
Process heater greater than
50, natural draft
|
0.10
|
|
|
Process heater greater than
50, mechanical draft
|
0.15
|
|
|
Process heater less than or
equal to 50
|
Combustion tuning
|
|
Other Liquid
Fuels
|
Process heater greater than 50,
natural draft
|
0.05
|
|
|
Process heater greater than
50, mechanical draft
|
0.08
|
|
|
Process heater less than or
equal to 50
|
Combustion tuning
|
(Source: Amended at 49 Ill.
Reg. 6355, effective April 23, 2025)
|