Public Act 104-0800 |
| HB5474 Enrolled | LRB104 19241 BDA 32687 b |
|
|
AN ACT concerning safety. |
Be it enacted by the People of the State of Illinois, |
represented in the General Assembly: |
Section 5. The Responsible Outdoor Lighting Control Act is |
amended by changing Sections 15, 20, and 25 as follows: |
(415 ILCS 200/15) |
Sec. 15. Outdoor lighting control. All new luminaires |
purchased with State funds after the effective date of this |
Act or installed after the effective date of this Act on a |
structure or land that is owned and managed by the Department |
of Natural Resources, including roadways, facilities, |
properties, nonhabitable structures, monuments, and public |
right-of-way spaces, including sidewalks, with the intended |
purpose of outdoor illumination must follow the following |
outdoor lighting control requirements: |
(1) Permanent outdoor luminaires must be fully |
shielded with an IES BUG rating and produce less than 1% of |
its emitted light above 80 degrees from the downward |
vertical direction of nadir. Light should not be emitted |
at an angle above 60 degrees from the downward vertical |
direction of nadir. |
(2) Luminaires must avoid light trespass by not |
exceeding an illuminance of one lux as measured at ground |
|
level both horizontally and vertically at the property |
boundary. |
(3) Luminaires purchased or installed on or before |
June 30, 2032 must have a correlated color temperature |
less than or equal to 2,700 Kelvin. All new luminaires |
purchased or installed after June 30, 2032 must have a |
correlated color temperature less than or equal to 2,200 |
Kelvin. In residential areas, dark sky locations, or |
environmentally sensitive areas, such as State parks and |
outdoor recreation facilities, correlated color |
temperature should be no more than 2,200 Kelvin. |
(4) Outdoor lighting must be minimized to no more than |
25% above ANSI/IES standards or United States Department |
of Transportation recommendations. |
(5) Facade lighting must be minimized to no more than |
25% above ANSI/IES standards, must project downward, and |
must not violate the light trespass limits in paragraph |
(2). |
(6) When the installation or replacement of roadway |
lighting is planned, the appropriate authority must |
determine whether reflective roadway markings or |
reflective signage is appropriate and safe for the |
situation in lieu of outdoor lighting. Reflectorized |
roadway markings, lines, warning signs, informational |
signs or other passive means must be used for roadway |
lighting, except at intersections of 2 or more streets or |
|
highways, unless it is determined that adequate safety |
cannot be achieved by reflective means. |
(7) No artificial lighting above one lux, as measured |
at ground level both horizontally and vertically, may |
trespass onto land or waterways designated or managed as |
habitat, reserve, natural area, open space, or wilderness. |
(Source: P.A. 103-1007, eff. 1-1-25.) |
(415 ILCS 200/20) |
Sec. 20. Exceptions. This Act does not apply if: |
(1) the luminaires are on a structure or land that is |
owned, supported, funded, leased, or managed by the State |
in a county or municipality that, by ordinance or |
resolution, has adopted provisions that are equal to or |
more stringent than the provisions of this Act; |
(2) a federal law or regulation preempts this Act; |
(3) a State agency determines a safety or security |
need exists that cannot be addressed by any other method; |
(4) fire, police, rescue, or repair personnel need |
light for temporary emergencies or road repair work; |
(5) it has been determined that a reasonable safety |
and security interest exists at correctional or hospital |
facilities that cannot be addressed by another method as |
long as it complies with existing standards, |
specifications, or policies; |
(6) navigational lighting systems and other lighting |
|
are necessary to comply with Federal Aviation |
Administration airside operations or nautical safety; |
(7) lamps greater than 2,700 Kelvin are used on active |
sports grounds or show grounds, but only for the duration |
of a practice, match, or event. Lamps emitting greater |
than 2,700 Kelvin under this paragraph must be positioned, |
angled, or shielded to prevent direct glare and light |
trespass onto neighboring property or properties, and the |
positioning, angling, or shielding must limit upward light |
emission to only the amount necessary to light the |
sporting or grounds activity; |
(8) flagpoles installed after the effective date of |
this Act are lit by means of a downward-facing lamp and |
using a lamp of 2,700 Kelvin or lower; |
(9) flagpoles installed on or before the effective |
date of this Act are upward-lit by partially shielded or |
unshielded luminaires using a lamp of 2,200 Kelvin or |
lower to minimize the impact of glare, light trespass, and |
sky glow and are converted to conform to requirements upon |
retrofitting; |
(10) the luminaires luminaries are existing decorative |
and ornamental lighting that serve historical purposes, |
but replacement luminaires luminaries for the existing |
decorative and ornamental lighting must meet the standards |
of this Act to the extent possible while maintaining |
historical fidelity; or |
|
(11) the luminaires luminaries are temporary seasonal |
holiday lighting lasting no longer than 45 days |
surrounding the holiday season; or . |
(12) it is necessary to use uplighting for statuary |
lighting and historical façade lighting. In cases where |
uplighting is the only viable solution for these items, |
the lighting should have a color corrected temperature of |
no more than 2,700 degrees Kelvin, must be minimized to no |
more than 25% above ANSI/IES standards, must not violate |
the light trespass limits in paragraph (2) of Section 15, |
and must be extinguished every night no later than 12:00 |
a.m. After January 1, 2027, any new placement or |
replacement of uplighting of State historic statuary and |
State historical façade lighting shall be approved by the |
State Historic Preservation Office. |
(Source: P.A. 103-1007, eff. 1-1-25.) |
(415 ILCS 200/25) |
Sec. 25. Other laws. If this Act conflicts with any other |
federal law, State law, or local ordinance controlling |
lighting, outdoor luminaires luminaries, signage, outdoor |
advertising, displays, or devices that is more stringent than |
the Act, then the federal law, State law, or local ordinance |
controls to the extent it is more stringent than the Act. |
(Source: P.A. 103-1007, eff. 1-1-25.) |